110V/240V Input 155W Ultraviolet Ballast for GHO64T5L UV Lamps
110V/240V Input 155W Ultraviolet Ballast for GHO64T5L UV Lamps
Product Parameters for this UV Disinfection Ballast
Start Mode | Pre-heat Start |
Operating Voltage Range | 99-264 |
Max Input Power | 190W |
Max Input Current | 0.84A @ 230V , 1.68@110V |
Lamp Power | 75-155W UV Lamp |
Lamp Current | 0.75-0.85A |
Operating Frequency | 40-70KHZ |
Preheat Time | 7.0-9.0 S |
Preheat Current | 1.0-1.3A |
Power Factor | ≥ 0.98 |
Efficiency | >90% |
Total Harmonic Distortion | <15% |
Crest Factor | <1.7 |
Ambient Humidity | 5%-85% |
Ambient Temperature | -15-40℃ |
Max Case Temperature | 70℃ |
Case Material | Aluminum Shell |
Safety Norm | EN61347-1-2-3, EN62493 |
LVD Norm | Low voltage Directive 2014/35/EU |
EMC Norm | EN55015, EN55014, GB17743, GB17625, EN61000-3-2 |
Certificates | CE/UL/CCC |
Product Features for this 4 pin uv ballast
1> This 155W Ultraviolet Ballast, is with high power factor. energy efficient.
2> This uv disinfection ballast is with worldwide universal voltage, can work with 110V and 230V input.
3> Reliable quality, less than 0.3% repair rate,within warranty.
4> We offer OEM and ODM service for this uv lamp ballast .
Dimension for this 155W Ultraviolet Ballast
Size: 250*65*40mm Carton size: 460*270*190mm (18PCS Load)
Wiring Diagram:
Loading Lamps, One Lamp Operation: GPH1554T5HO GHO64T5L TUV64T5HO
Loading Lamps, Two Lamps Operation: GPH846T5HO GPH893T5HO GHO36T5L TUV36T5HO TUV55WHO TUV75WHO
Cautions:
1. Please make sure the power is off when you install or maintain the ballast
2. The distance between ballast and lamp tube should no longer than 5M.
3. The suggested wire specific: diameter 0.5-1mm, wire stripping 0.8-1mm
4. The aluminum shell should be grounded.