How to Verify UV Lamp Compatibility for Your BWTS: A Step-by-Step Guide

Desmi UV Lamp Replacements.jpg

The UV lamp functions as the critical disinfection component in your Ballast Water Treatment System, converting electrical power into the specific ultraviolet spectrum required to neutralize invasive aquatic organisms and meet stringent IMO/USCG standards. Selecting the precisely compatible replacement lamp is therefore not just a maintenance consideration—it's a fundamental operational necessity that protects your compliance status, prevents system damage, and ensures effective treatment performance.

To verify a UV lamp's compatibility with a Ballast Water Treatment System (BWTS), you must match the lamp's electrical, physical, and performance characteristics to the BWTS manufacturer's specifications

Mismatching the lamp can lead to unsafe operating conditions, premature lamp or ballast failure, and most critically, ineffective disinfection that violates regulatory standards. At Fiver Environment Group Ltd, we've specialized in manufacturing high-quality MP UV lamp replacements for over a decade. Here is a step-by-step guide on how to verify compatibility.



Your 5-Step Compatibility Verification Checklist


Step 1: Identify Your System & Original Lamp

Start with these sources:

BWTS Manual – Your most reliable reference

BWTS Manual .jpg

Existing Lamp Part Number – Look for engraved codes on the lamp end-cap

Lamp Part Number.jpg

BWTS Model Plate – Located on the control panel or treatment unit

BWTS Model Plate.jpg


Common Systems We Support:

✅ Alfa Laval PureBallast | ✅ BSKY | ✅ Desmi | ✅ Elite | ✅ Miura | ✅ Panasia | ✅ And other brands

Pro Tip: Take clear photos of your existing lamp and BWTS model plate – our technical team can identify compatible replacements instantly.


Step 2: Match Electrical Specifications (The Most Critical Step)


SPECIFICATIONWHAT TO CHECKWHY IT MATTERS
VoltageOperating voltage rangePrevents ballast damage & ensures proper ignition
WattageExact power rating (1kW-60kW range)Maintains correct UV output for effective treatment
Lamp TypeMP (Medium Pressure) vs LP (Low Pressure)Never mix types – MP lamps require specific ballasts

⚠️ Warning: Using a voltmeter on a running lamp requires a trained electrician. When in doubt, consult professionals.


Step 3: Verify Physical Dimensions

A perfect physical fit ensures optimal performance:

Arc Length – Must match original to cover entire treatment chamber

Diameter – Critical for proper quartz sleeve fitting

Lamp Head & Pin Configuration – Must match your system's connectors

Our Advantage: Fiver Environment offers custom pin/connector arrangements and precise dimensional matching for hard-to-find replacements.



Step 4: Confirm Performance Specifications

Your BWTS was type-approved with specific performance criteria. Replacement lamps must maintain:

UV Spectral Output – Equivalent broad-spectrum disinfection

UV Dose Delivery – Maintains regulatory compliance

UV Intensity – Prevents false system alarms

Industry Insight: Many "compatible" lamps fail here. We provide spectral analysis reports and performance certifications with every lamp.


Step 5: Consult with Experts

Always verify with your supplier. When contacting us at Fiver Environment:

Provide your BWTS make/model

Share original lamp part number

Include ballast information if available

Mention any special operating conditions


We'll cross-reference our compatibility database of 500+ BWTS models and provide:

✅ Compatibility confirmation

✅ Technical specifications sheet

✅ Installation guidance

✅ Performance warranty



Why Choose Fiver Environment Group Replacement Lamps?

Guaranteed Compatibility

Our lamps are engineered to match OEM specifications for: Alfa Laval; BSKY; Desmi; Elite; Miura; Panasia...And most major BWTS brands.

Quality You Can Trust

  • ✅ ISO 9001 certified manufacturing, 

  • ✅ Rigorous performance testing; 

  • ✅ Longer operational life than many OEM lamps; 

  • ✅ Competitive pricing – Save over 50% vs. Original

Global Support

  • ✅ 24/7 technical assistance

  • ✅ Emergency shipping available

  • ✅ Comprehensive documentation

  • ✅ Regulatory compliance support



Frequently Asked Questions

Q: Will using your lamps void my BWTS warranty?

A: Under US law (and similar regulations in many other countries), manufacturers cannot void a warranty simply because you use aftermarket parts, provided those parts meet or exceed OEM specifications. We design our lamps to be direct functional equivalents that maintain your system's original performance standards.

Q: How do I know if a lamp is truly compatible?

A:  All Marine UV lamps from Fiver are developed from genuine OEM specifications and are engineered to be direct functional equivalents. We ensure 100% compatibility through a rigorous verification process that matches your specific Ballast Water Treatment System (BWTS) model.

Q: What if my BWTS model isn't listed?

A: Contact us anyway! Our database covers hundreds of models not listed on our website. We specialize in hard-to-find replacements.

Q: Do you offer technical installation support?

A: Yes. We provide detailed installation guides and offer remote technical support for our customers.



Need Help Verifying Compatibility?

Don't guess – get expert verification!

Contact Fiver Environment Group Today:

Website: www.fiveruvc.com

Email: jerry@fiveruvc.com

Phone: +86-18028699987

Quick Quote Form: [Click to contact]

Free Compatibility Check: Send us your BWTS details and existing lamp information for a no-obligation compatibility verification within 24 hours. Contact our sales team for Ballast Water UV Lamps Catalog.



















Post time:2026-01-13

  • No previous
  • NEXT:Types of Ballast Water Treatment Systems Pros & Cons

  • RELATED NEWS